Environment  | Working temperature  | -30℃~+55℃  | 
Height above sea level  | 2000m  | |
Protection class  | IP54  | |
Electrical  | Input voltage  | AC400V±10%  | 
Rated power  | 60kW,90kW,120kW,150kW,180kW  | |
Rated output voltage  | CCS2 DC: 200-750V  | |
Structure  | Charging groups  | Double-gun round charge (CCS2)  | 
Cable Length  | 5m,8m,10m  | |
Function  | Charging mode  | Auto charge, charge by amount, charge by power, charge by set time  | 
Communications interface  | 4G ,WIFI,Ethernet  | |
User interface  | LCD display touch screen  | |
Backstage monitoring  | OCPP1.6  | |
Safety  | Protective design  | Overvoltage protection, under-voltage protection, overload protection, short-circuit protection, leakage protection, grounding protection, high temperature protection, low temperature protection, lightning protection safeguard  | 
Based on the criteria  | IEC 62196, IEC 61851, ISO/IEC 15118, DIN SPEC 70121-2014  |